ACL Interference Screw Bio Composite
ACL Interference Screw Bio Composite

ACL Interference Screw Bio Composite

MOQ : 100 Pieces

ACL Interference Screw Bio Composite Specification

  • Category
  • Orthopedic Surgical Implant
  • Implants Type
  • Orthopedic Implant (ACL Interference Screw)
  • Material
  • Bio Composite (PLGA and -TCP)
  • Sterilized
  • Yes
  • Sterilization Mode
  • Gamma Sterilized
  • Stent Location
  • Knee Joint (Anterior Cruciate Ligament)
  • Physical Shape
  • Cannulated, Threaded Screw
  • Curved Angle
  • Straight
  • Flexible
  • No
  • Soluble
  • Partially Resorbable
  • Recyclable
  • No
  • Usage
  • ACL Reconstruction Surgery
  • Dimension (L*W*H)
  • Available in multiple lengths (20-40 mm) and diameters (7-10 mm)
  • Grade
  • Medical grade
  • Color
  • Off-white/Light beige
  • Weight
  • Lightweight, specific weight varies by size
  • Radiolucency
  • Radiolucent with visible marker
  • Pore Structure
  • Microporous for bone ingrowth
  • Thread Profile
  • Deep thread for secure graft fixation
  • Shelf Life
  • Up to 5 years
  • Insertion Tool Compatibility
  • Compatible with standard driver system
  • Packaging
  • Individually packed in sterile pouch
  • Biocompatibility
  • Non-toxic, non-immunogenic
  • Compliance Standards
  • ISO 13485, CE Marked
  • Resorption Time
  • 12-24 months (depending on patient factors)
 

ACL Interference Screw Bio Composite Trade Information

  • Minimum Order Quantity
  • 100 Pieces
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 5000 Pieces Per Month
  • Delivery Time
  • 10 Days
  • Main Domestic Market
  • All India
 

About ACL Interference Screw Bio Composite



Discover the rare opportunity to access the ACL Interference Screw Bio Composite at the best price. This decorated orthopedic implant is a crackerjack solution for ACL reconstruction, offering astounding graft fixation with its deep thread profile. Crafted from a bio composite of PLGA and -TCP, it is radiolucent with a visible marker, partially resorbable, and boasts microporous architecture for optimal bone ingrowth. Individually packed in sterile pouches, this non-toxic, CE-marked screw meets ISO 13485 standards and has a shelf life of up to 5 years. Available in multiple dimensions, it is compatible with standard driver systems for seamless surgical implementation.

Advanced Material for Astounding ACL Fixation

The ACL Interference Screw Bio Composite is meticulously engineered from medical-grade PLGA and -TCP. Its microporous design supports robust bone ingrowth, while deep threading ensures secure graft anchorage. As a partially resorbable, non-toxic, and non-immunogenic implant, it delivers excellent biocompatibility for ACL reconstruction. Suitable for orthopedic surgery, this straight, cannulated screw is a stellar choice for surgeons seeking reliability and patient safety.


Premium Packaging and Seamless Export Solutions

We offer individually sterilized pouches to preserve the integrity and sterility of each ACL Interference Screw Bio Composite. With substantial supply ability, our export market coverage ensures efficient transportation to clients across India and beyond. Flexible payment terms are available to facilitate smooth transactions with distributors, importers, manufacturers, service providers, suppliers, and traders. Premium packaging and logistics guarantee satisfaction for every order.


FAQ's of ACL Interference Screw Bio Composite:


Q: How does the ACL Interference Screw Bio Composite support bone healing?

A: The screw's microporous architecture facilitates bone ingrowth, promoting natural integration and healing at the surgical site. Its partially resorbable composition gradually dissolves within 12-24 months, reducing long-term foreign body presence.

Q: What are the advantages of radiolucency with a visible marker in this implant?

A: Radiolucency allows clear imaging without obstruction on X-rays, while the visible marker provides precise placement verification during surgery. This feature helps surgeons achieve optimal alignment and fixation accuracy.

Q: Where can the ACL Interference Screw Bio Composite be applied?

A: This screw is primarily designed for ACL reconstruction surgeries in the knee joint. It is compatible with standard driver systems and can be used by trained orthopedic surgeons for secure graft fixation.

Q: When should I consider using this bio composite interference screw?

A: It is ideal for use in anterior cruciate ligament reconstruction procedures requiring dependable fixation, especially if long-term biocompatibility and gradual resorption are desired.

Q: What is the process for ordering and receiving the ACL Interference Screw Bio Composite?

A: Orders can be placed through our distribution network or direct contact. We provide sterile, individually packaged screws with prompt transportation and export market solutions, ensuring reliable supply and delivery.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Arthroscopy Implants Category

Medium Spike Ligament Staple

Medium Spike Ligament Staple

Minimum Order Quantity : 100 Pieces

Sterilized : Yes

Usage : Used for fixation of ligament or tendon to bone, especially in orthopedic surgeries

Material : Other, Stainless Steel (Medical Grade 316L)

Soluble : No

Dimension (L*W*H) : 45 mm x 8 mm x 35 mm (approximate)

Large Spike Ligament Staple

Large Spike Ligament Staple

Minimum Order Quantity : 100 Pieces

Sterilized : Other, NonSterile (To be sterilized prior to surgical use)

Usage : Surgical Fixation of Ligaments in Orthopedic Procedures

Material : Other, Stainless Steel (typically medical grade 316L or equivalent)

Soluble : No

Dimension (L*W*H) : Approx. 25mm x 10mm x 2mm (may vary by manufacturer)

Flexrope Adjustable Loop Button

Flexrope Adjustable Loop Button

Minimum Order Quantity : 100 Pieces

Sterilized : Yes

Usage : Ligament Reconstruction, ACL/PCL Fixation, Soft Tissue Attachment

Material : Other, Polyester (Rope) & Titanium Alloy (Button)

Soluble : No

Dimension (L*W*H) : Button Diameter 13 mm, Loop Adjustable from 15 mm to 45 mm

Flexrope Plus Adjustable Loop Button With Flipping Suture

Flexrope Plus Adjustable Loop Button With Flipping Suture

Minimum Order Quantity : 100 Pieces

Sterilized : Yes

Usage : Used in ligament reconstruction surgery for fixation of grafts to bone

Material : Other, High Tensile Strength Polyester & Titanium Alloy

Soluble : No

Dimension (L*W*H) : Button: ~12 mm x 4 mm x 3 mm; Loop: Adjustable up to ~60 mm



Back to top